HomeProductsSmart MeteringLoRa Three-phase DIN Rail Energy Meter
LoRa Three-phase DIN Rail Energy Meter
Electricity Meters

LoRa Three-phase DIN Rail Energy Meter

The LoRa Three-phase DIN Rail Energy Meter meets the technical requirements of IEC 62053-21 for Class 1 three-phase active energy meters. It measures voltage, current, power, power factor, energy and total energy in 50Hz or 60Hz three-phase AC networks.

Built-in LoRaWAN and RS-485 communication, with MODBUS-RTU support, enable integration into AMR systems. The reliable, energy-saving, compact and lightweight meter is easy to install and is suitable for energy-saving, power, telecommunications, railway, transport, environmental protection, petrochemical and steel applications.

Enquire About This Product
01 / PRODUCT FEATURES

Product at a glance

Comprehensive AC Data Acquisition

  • Measures three-phase AC voltage, current, power and energy.

High-accuracy RMS Measurement

  • Uses a dedicated measurement chip and RMS measurement for high accuracy.

Built-in LoRaWAN Communication

  • Built-in LoRaWAN module and one RS-485 communication interface.

Standard Modbus Compatibility

  • Uses standard MODBUS-RTU for compatibility and convenient programming.

Wide Operating Voltage and Reverse-connection Protection

  • AC80-265V operating voltage with reverse-connection protection; reverse power connection does not damage the module.

High Isolation Withstand Voltage

  • AC withstand voltage up to 2000V.

Residual Current Detection

  • Includes one residual current measurement channel.

Dot-matrix LCD

  • Dot-matrix LCD display.

Industrial Reliability

  • Industrial-grade chips, a built-in watchdog, lightning protection and interference protection support reliable operation.

Current Transformer Options

  • Optional single-turn through-core or split-core current transformers in different ratings.
02 / SPECIFICATIONS

Technical specifications

DescriptionValue
AC Input Voltage Options
100V / 220V / 380V
Current Range and CT Options
5A / 50A / 100A / 200A; optional external split-core CT models.
Signal Processing
Dedicated measurement chip with 24-bit AD sampling.
Overload Capacity
1.2 times range continuously; no damage within 5 times current and 2 times voltage range for transients <200ms.
Input Impedance
Voltage channel >1 kΩ/V; current channel ≤100mΩ.
Wireless Communication
LoRaWAN
RS-485 Interfaces
One RS-485 interface
Communication Protocol
MODBUS-RTU
Serial Data Format
Software-selectable: n,8,1 / e,8,1 / o,8,1 / n,8,2; default n,8,1
RS-485 Baud Rate
Selectable 1200 / 2400 / 4800 / 9600bps; default 9600bps.
Metering Output Data
Voltage, current, power, energy, power factor and frequency; details are defined in the Modbus data register list.
Measurement Accuracy
Voltage and current: ±1.0%; active energy: Class 1.
Interface Isolation
RS-485, supply power, voltage input and current input are mutually isolated; isolation withstand voltage 2000VDC.
Supply Voltage Options
100V / 220V / 380V; voltage line 100-380V.
With AC220V supply, peak voltage must not exceed 265V.
Typical Power Consumption
≤2W
Operating Temperature
-20°C to +60°C
Storage Temperature
-40°C to +85°C
Altitude
0-3000m
Temperature Drift
<100ppm/°C
DIN Rail Installation
4P enclosure, 35mm DIN rail
Switching Output
One relay open-circuit output with voltage and current overload alarm protection output.
LET’S TALK ABOUT YOUR REQUIREMENTS

Interested in LoRa Three-phase DIN Rail Energy Meter?

Contact our team for product availability, specifications and technical documentation.

Contact Our Team